Oil-immersed amorphous alloy transformer

This amorphous alloy oil-immersed transformer uses amorphous alloy as core material, with insulating oil for cooling and insulation. It features extremely low core loss and remarkable energy saving. The fully sealed structure prevents oil leakage with maintenance-free performance. Low temperature rise slows insulation aging, suitable for outdoor power distribution, industrial & commercial sites and new energy projects. It is eco-friendly with lower overall power consumption during service life.

Request a quote

Product Overview

This amorphous alloy oil-immersed transformer uses amorphous alloy as core material, with insulating oil for cooling and insulation. It features extremely low core loss and remarkable energy saving. The fully sealed structure prevents oil leakage with maintenance-free performance. Low temperature rise slows insulation aging, suitable for outdoor power distribution, industrial & commercial sites and new energy projects. It is eco-friendly with lower overall power consumption during service life.

Model and Meaning

Transformer Normal Service Conditions

Altitude: not exceeding 1000m

Ambient temperature: Maximum air temperature: +40℃        Maximum daily average air temperature: +30℃

Maximum annual average air temperature: +20℃

Minimum outdoor air temperature: −25℃

Power voltage waveform approximates sine wave; three-phase power voltage is approximately symmetrical Installation environment: no obvious contamination

Seismic ground acceleration ag: horizontal value below 3m/s², vertical value below 1.5m/s²

Indoor usage

Note: If special service conditions outside the above normal ranges are required, relevant conditions shall be stated when requesting quotation and placing orders

Technical Parameters

S(B)H15 Series 6kV/ 10kV Class Amorphous Alloy Oil-Immersed Transformers

Rated capacity (kVA) Voltage Combinationed Tap Range Vector Group Symbol Loss (W) No-load current (%) Impedance voltage (%) Weight (kg) Overall dimension L×W×H Track gauge Longitudinal / Transverse
HV(kV) HV Tap Range % LV(kV) No-load Loss Load Loss Body(kg) Oil(kg) Total(kg)
30 11
10.5
10
6.3
6
±5
±2×2.
0.4 Dyn11 33 630 1.5 4.0 240 80 410 920×600×980 400×550
50 43 910 1.2 310 110 510 950×620×1040
63 50 1090 1.1 350 125 570 990×670×1040
80 60 1310 1 410 135 630 1030×720×1040 400×660
100 75 1580 0.9 475 150 720 1060×770×1070
125 85 1890 0.8 550 170 830 1060×900×1070
160 100 2310 0.6 630 190 960 1060×930×1150
200 120 2730 0.6 670 210 1040 1100×930×1170 550×820
250 140 3200 0.6 750 240 1160 1180×1010×1180
315 170 3830 0.5 810 264 1240 1200×1010×1180
400 200 4520 0.5 860 290 1330 1270×1160×1200
500 240 5410 0.5 950 320 1460 1450×1240×1330 820×1070
630 320 6200 0.3 1120 380 1860 1450×1240×1330
800 380 7500 0.3 4.5 1340 410 2230 1520×1380×1460
1000 450 10300 0.3 1620 540 2700 1720×1460×1510
1250 530 12000 0.2 1900 640 3180 1780×1500×1690
1600 630 14500 0.2 2560 680 4240 1880×1540×1970
2000 750 18300 0.2 5.0 2900 980 4920 2080×1580×1970
2500 900 21200 0.2 3940 1160 6560 2350×1580×2020

Note: The overall dimensions provided in this manual are for type selection reference only. Final dimensions shall be subject to the product outline drawing.

Rated capacity (kVA) Voltage Combinationed Tap Range Vector Group Symbol Loss (W) No-load current (%) Impedance voltage (%) Weight(kg) Overall dimension L×W×H Track gauge Longitudinal / Transverse
HV(kV) HV Tap Range % LV(kV) No-load Loss Load Loss Body (kg) Oil (kg) Total (kg)
30 11
10.5
10
6.3
6
±5
±2×2.5
0.4 Dyn11 33 630 1.5 4.0 240 80 410 920×600×980 400×550
50 43 910 1.2 310 110 510 950×620×1040
63 50 1090 1.1 350 125 570 990×670×1040
80 60 1310 1.0 410 135 630 1030×720×1040 400×660
100 75 1580 0.9 475 150 720 1060×770×1070
125 85 1890 0.8 550 170 830 1060×900×1070
160 100 2310 0.6 630 190 960 1060×930×1150
200 120 2730 0.6 670 210 1040 1100×930×1170 550×820
250 140 3200 0.6 750 240 1160 1180×1010×1180
315 170 3830 0.5 810 264 1240 1200×1010×1180
400 200 4520 0.5 860 290 1330 1270×1160×1200
500 240 5410 0.5 950 320 1460 1450×1240×1330 820×1070
630 320 6200 0.3 1120 380 1860 1450×1240×1330
800 380 7500 0.3 4.5 1340 410 2230 1520×1380×1460
1000 450 10300 0.3 1620 540 2700 1720×1460×1510
1250 530 12000 0.2 1900 640 3180 1780×1500×1690
1600 630 14500 0.2 2560 680 4240 1880×1540×1970
2000 750 18300 0.2 5.0 2900 980 4920 2080×1580×1970
2500 900 21200 0.2 3940 1160 6560 2350×1580×2020

Notes:

①For a three-phase three-limb core, Yyn0 connection group mayalso be adopted as required.

②For transformers with rated capacity up to 500kVA, the load loss values above the slash in the table apply to Dyn11 or Yzn11 connection groups; the load loss values below the slash apply to Yyn0 connection group.