Skip to main content
JOHNN

Switchgear Cabinets

Chinese box type substation

Chinese box type transformer substation is different from American box type transformer substation and European box type transformer substation. The unique R method high-voltage connection, which is the first in the industry, has China's independent intellectual property rights, and fully demonstrates the extraordinary features of the Chinese box type transformer: safety, reliability, convenience, and environmental protection. At present, it has been widely used in 35KV power transformation and distribution fields such as photovoltaic and wind power.

Request a quote

Product Overview

Chinese box type transformer substation is different from American box type transformer substation and European box type transformer substation. The unique R method high-voltage connection, which is the first in the industry, has China’s independent intellectual property rights, and fully demonstrates the extraordinary features of the Chinese box type transformer: safety, reliability, convenience, and environmental protection. At present, it has been widely used in 35KV power transformation and distribution fields such as photovoltaic and wind power.

Product Highlights

1.No oil draining or refilling required, eliminating maintenance troubles of American-type box substations.

2.System operation keeps running without power outage, power generation remains unaffected.

3.The transformer is shielded from direct sunlight to achieve higher generating efficiency.

4.Insulating oil stays free from contamination, securing stable performance for 20 years.

5.Safe, convenient operation & maintenance, adaptable to harsh weather conditions.

6.Full thermal insulation protection, with natural ventilation for heat dissipation.

Electrical System

Technical Parameters

Model JSJ-1000/35 JSJ-1500/35 JSJ-2000/35
Total power(KW) 1000 1500 2000
AC input (270V+270V)Photovoltaic ~800V(Wind Power) ~800V(Wind Power)
AC boost 35KV~38.5KV 35KV~38.5KV 35KV~38.5KV
High voltage switch cabinet GGR-25A/40.5 GGR-35A/40.5 GGR-50A/40.5
Energy saving transformer S11-1000KVA/35 S11-1600KVA/35 S11-2200KVA35
Box transformer measurement and control RS485 RS485 RS485
Overall dimensions (length×wide×high) 3600×2430×2900 (for reference only) 4300×3000×2900 (for reference only) 4300×3000×2900 (for reference only)
Weight(KG) 6000(for reference only) 7000(for reference only) 8000(for reference only)

Comparison Among 35kV American-type, European-typeand Chinese-type Transformers

Compare items American box type substation European box type substation Chinese box type substation
Maintenance,overhaul oil drainage and refueling Mandatory(serious defect) No No
Power failure of maintenance and repair system No Mandatory(serious defect) No
Solar exposure affects power generation Meeting can’t can’t
The switch arc extinguishing oil is polluted Meeting can’t can’t
Power generation reduction due to system outage can’t Meeting can’t
Potential safety hazard of misoperation in different places Impossible Possible Impossible
Heat dissipation of transformer fan No Essential No
Shell thermal insulation None have have
Weather impact of operation and maintenance Have No. No.
Cost of three types of box type substation Slightly low Slightly higher Slightly higher