35kV Oil-immersed transformer

This 35kV oil immersed power transformer is applicable to power distribution of substations and industrial & mining plants.

Insulating oil serves for heat dissipation and electrical insulation. Featuring stable operation, strong overload capacity, reliable cooling structure and easy maintenance, it can supply power steadily under long-term outdoor conditions, and is widely used for high-voltage power transmission and distribution.

Request a quote

Product Overview

This 35kV oil immersed power transformer is applicable to power distribution of substations and industrial & mining plants.

Insulating oil serves for heat dissipation and electrical insulation. Featuring stable operation, strong overload capacity, reliable cooling structure and easy maintenance, it can supply power steadily under long-term outdoor conditions, and is widely used for high-voltage power transmission and distribution.

Model and Meaning

Transformer Product Standards

GB 1094.1-1996

GB 1094.2-1996

GB 1094.3-2003

GB 1094.5-2008

GB/T 6451-2008

GB/T 7595-2008

JB/T 3837-2010

Transformer Normal Service Conditions

The height above the sea level is below 1000m;

Ambient temperature;

Highest air temperature +40℃ ;

Highest daily average air temperature+30℃ ;

Highest annual average air temperature +20℃ ;

Lowest outdoor air temperature -25℃ ;

Technical Parameters

S11 series level 35kV oil-immersed transforimers

50kva 1600kva 3-phase duplex winding non-excited tap-changing distribution transformer

Rated capacity (kVA) Voltage Combination and Tap range Vector Group Symbol No-load Loss(kW) Load Loss(kW) No-load current (%) Short-circuit Impedance Voltage (%)
HV(kV) HV Tap Range % LV(kV)
50 35 ±5 0.4 Dyn11 Yyn0 0.19 1.21/1.15 2 6.5
100 0.26 2.01/1.92 1.8
125 0.31 2.38/2.26 1.7
160 0.32 2.82/2.69 1.6
200 0.39 3.33/3.16 1.5
250 0.46 3.95/3.76 1.4
315 0.55 4.76/4.53 1.4
400 0.66 5.75/5.47 1.3
500 0.77 6.92/6.58 1.2
630 0.94 7.87 1.1
800 1.11 9.41 1
1000 1.3 11.54 1
1250 1.58 13.94 0.9
1600 1.91 16.67 0.8

Note 1: Rated capacity 500kVA and below transformer, the load loss above the oblique line in the table applies to Dyn11 or Yzn11; the load loss below the oblique line applies to Yyn0.

Note 2: According to requirements, the transformer can supply HV tap change ±2×2.5%.

Note 3: other dimension is designed according to customers.

630kva ~31500kva triple phase duplex winding non exciting regulating power transformer

Rated capacity(kVA) Voltage Combination and Tap range Vector Group Symbol No-load Loss(kW) Load Loss(kW) No-load current (%) Shortcircuit Impedance Voltage (%)
HV(kV) HV Tap Range % LV(kV)
630 35 ±5 3.15
6.3
10.5
Yd11 0.94 7.87 1.1 6.5
800 1.11 9.41 1.0
1000 1.3 11.54 1.0
1250 1.58 13.94 0.9
1600 1.91 16.67 0.8
2000 2.45 18.38 0.7
2500 2.88 19.67 0.6
3150 35~38.5 ±5 3.15
6.3
10.5
3.42 23.09 0.56 7
4000 4.07 27.36 0.56
5000 4.86 31.38 0.48
6300 5.9 35.06 0.48 7.5
8000 35~38.5 ±2×2.5 3.15
3.3
6.3
6.6
1.0511
Yd11 8.1 38.48 0.42
10000 9.79 45.32 0.42
12500 11.34 53.87 0.40 8
16000 13.68 65.84 0.40
20000 16.2 79.52 0.40
25000 19.15 94.05 0.32
31500 22.75 112.86 0.32

Note 1: Outline dimension is designed according to requirements